Wastewater Treatment Case: Chemical Sewage Treatment for Daily Chemical Company

Throughout the entire wastewater treatment process, operation and monitoring are carried out through an automated control system, which facilitates real-time monitoring of various parameters during processing, timely adjustment of operating status, and improvement of operational management efficiency and stability.

Processing Requirements
Raw Water:Daily chemical wastewater;
Capacity:12 T/D;
Inlet Water: COD:1000mg/L
Outlet Water:
COD:≤500mg/L;
SS:≤40mg/L;
Animal and Vegetable Oils≤100mg/L;
PH:6-9.

Process Flow

Process Characteristics

Fenton Reaction Enhanced Pretreatment: Fenton reaction tank is set up, and the strong oxidizing hydroxyl radicals generated by Fenton reagent can effectively degrade the recalcitrant organic pollutants in chemical wastewater, improve the biodegradability of wastewater, and create favorable conditions for subsequent biochemical treatment.

A/O Biological Process: Utilizing denitrification in the anoxic zone and nitrification in the aerobic zone, the total nitrogen removal rate can reach 60%-85%. The aerobic zone can efficiently degrade organic matter in the water into carbon dioxide and water;

MBR Membrane Deep Treatment: MBR technology combines biological treatment with membrane separation, which has high solid-liquid separation efficiency, can effectively remove suspended solids and large molecular organic matter, and ensure the stability of effluent water quality.

Latest Posts

Do you need a quotation?

Please leave a message or send us an email:[email protected]